Skip to the main content.

Owner Approach

Focused on owner’s requirements, Conspectus offers an accurate, transparent view of how decisions made during the design process will ultimately impact project cost, construction quality, and building operations.

Services 

Owner Approach | Conspectus

 

Contact Us

    Architect Approach

    Focused on architect's requirements, Conspectus offers an accurate, transparent view of how decisions made during the design process will ultimately impact project cost, construction quality, and building operations.

    Services 

    Architects | Conspectus Inc

     

    Contact Us

      Design-Builder Approach

      Focused on design-builder's requirements, Conspectus offers an accurate, transparent view of how decisions made during the design process will ultimately impact project cost, construction quality, and building operations.

      Services 

      Design-Builders | Conspectus Inc

       

      Contact Us

        Construction Manager Approach

        Focused on construction manager's requirements, Conspectus offers an accurate, transparent view of how decisions made during the design process will ultimately impact project cost, construction quality, and building operations.

        Services 

        Construction Managers | Conspectus Inc

         

        Contact Us

          1 min read

          Uniform Stair Risers

          Blog 2011.03.08 hotel egress stairThe International Building Code (IBC) Section 1009.4.4 requires stair risers and tread widths to be uniform height and width within a tolerance of 3/8 inch throughout the entire flight of stairs. Why is this important? The reason became instantly apparent the first time I climbed these egress stairs in a 1912 hotel as the most convenient path between meeting rooms on adjacent floors.

          Uniform risers and tread widths allow people to use stairs without concentrating on their gait. The first few steps set the pattern, that once recognized is easily repeated until the exit is reached. Uniformity can help speed descending stairs in an emergency. Changing the pattern may cause people to lose their balance, trip, and potentially fall.

          Fortunately, I was climbing, so I was able to catch myself as I nearly fell from the drastic change in riser height. The typical riser is about 6 inches high. The greatest riser is more than 8 inches and the least about 3 inches. The minimum riser is 4 inches by IBC Section 1009.4.2.  Climbing, the riser sequence is 6 - 8 - 3 - 6 while making the turn at the intermediate landing. After the first time, I learned. So did others. We did not avoid the stairs, but the travel was cautious and deliberate. Every time I was on the stair with others, reminders were abundant.

          Now imagine an emergency, without normal lighting, and an assembly occupancy floor trying to use these stairs. A single trip-and-fall would cause exiting chaos and probably severe injuries.